Key Advantages

  • External hex
  • Wide range of choices: Ø3.5/4.0/4.5/5.0/6.0
  • Compatible with ExFeel external prosthesis
AnyOne® for any implantologist & any patient

Offering a better experience for both dentists & patients.
For dentists: convenient implant placement, strong initial stability, excellent soft & hard tissue response, & shorter overall treatment time.
For patients: minimally invasive surgery with less pain, shorter healing time, & better esthetic results.

4. AnyOne Handpiece & Ratchet

  • Compatible with AnyOne Internal & AnyOne External (small, regular, wide)

5. AnyOne External fixture mount

  • Functions as ‘bolt’ & mounted on fixture during placement, then removed when placing cover screw
  • Insertion torque value for AnyOne External fixture mount should not exceed 160Ncm
  • Markings on AnyOne External fixture mount estimate placement depth as follows:
    1.5mm: cover screw height
    3.5mm: gingival height
    4mm: healing height
Designed for predictable initial stability

Wide selection of diameters (Ø3.5 to Ø6.0) & lengths (7mm to15mm) for all bone conditions

Simplified surgical protocol for predictable initial stability

Drilling sequence guide
Various abutment choices

· Flexible choices for all cases
· Compatible with small or regular-size Branemark abutments
· Compatible with 3i wide-type abutments

KnifeThread ®

Special thread design & super self-tapping create better initial stability in any compromised bone situation.

This distinctive design enables bone condensing, gentle ridge expansion, maximized compressive force resistance, & minimized shear force production.1

+ Discover more about KnifeThread®
- Strong
- Faster
- Safer

To promote secondary stability, all AnyOne® implants have a special extra surface coating called Xpeed. This unique hydro-thermal incorporation of calcium ions has already been proven to activate osteoblasts and accelerate osseointegration, essential for secondary stability.2,3
Plus, Xpeed provides an important quality check to avoid any acid residue (BLUE means NO acid residue!)

+ Discover more about Xpeed®
References
  1. McCullough JJ , Klokkevold PR The effect of implant thread design on implant stability in the early post-operative period
    https://www.ncbi.nlm.nih.gov/pubmed/27699890
  2. S.-Y. Lee, The cytocompatability and osseointegration of Ti implants with Xpeed surfaces
    http://www.megagenitalia.it/wp-content/uploads/2017/02/4.-COIR-2011-XPEED.pdf
  3. F.G. Mangano Early bone formation around immediately loaded implants with nanostructured calcium-incorproated and machined surface: a randomized controlled histologic and histophometric study in human posterior maxilla
    https://www.ncbi.nlm.nih.gov/pubmed/28154996