HQ / Factory : 45, Secheon-ro 7-gil Dasa-eup Dalseong-gun Daegu TEL : +82-2-6003-2011
MEGA’GEN TOWER: 607 Seolleung-ro, Gangnam-gu, Seoul, Korea TEL : +82-2-6003-2011
FOR SALES & BUSINESS FOR OTHER COMMENTS.
COPYRIGHT(C)MEGA’GEN IMPLANT CO.,LTD.ALL RIGHTS RESERVED
Key Advantages
- Optimum transgingival cuff enables successful 1-stage surgery
- Single prosthetic connection for all fixture sizes (8° internal 3.1 Octa connection)
AnyOne® for any implantologist and any patient
Offering a better experience for both dentists & patients
For dentists: convenient implant placement, strong initial stability, excellent soft & hard tissue response, & shorter overall treatment time
For patients: minimally invasive surgery with less pain, shorter healing time, & better esthetic results
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/01.jpg)
![](/wp-content/uploads/sites/26/2019/10/txt-5.jpg)
![](/wp-content/uploads/sites/26/2019/10/txt-6.jpg)
![](/wp-content/uploads/sites/26/2019/10/txt-7.jpg)
![](/wp-content/uploads/sites/26/2019/10/txt-8.jpg)
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/bitmap.png)
Variety of fixtures for predictable initial stability
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/group-4-1.png)
Wide selection of diameters (Ø3.5 to Ø6.0) & lengths (7mm to 15mm) for all bone conditions
Plus, 2 thread depths (same core diameter)
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/bitmap-2.jpg)
Regular thread for easy placement in hard bone (D1 D2) ∅3.5, ∅4.0, ∅4.5, ∅5.0
Deep thread for higher initial stability in soft bone (D3 D4) ∅4.5, ∅5.0
KnifeThread ®
Special thread design & super self-tapping create better initial stability in any compromised bone situation.
This distinctive design enables bone condensing, gentle ridge expansion, maximized compressive force resistance, & minimized shear force production.1
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/bitmap-1.png)
Simplified drilling sequence for predictable initial stability
All fixture sizes have same Octa prosthetic connection with 8° internal hex connection
- Flexible choices for all cases
- Compatible with ExFeel internal prosthetics
- Compatible with small or regular-size ITI abutments
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/09/group-5.jpg)
References
- McCullough JJ , Klokkevold PR The effect of implant thread design on implant stability in the early post-operative period
https://www.ncbi.nlm.nih.gov/pubmed/27699890
![](https://imegagen.com/tha/wp-content/uploads/sites/26/2019/08/group-copy.png)